6. CALIBRATION
6.1. Introduction
Calibration associates the angle of each robot axis with the pulse count value supplied from the absolute Pulsecoder connected to the corresponding axis motor. To be specific, calibration is an operation for obtaining the pulse count value, corresponding to the home position.
Calibration is factory-performed. It is unnecessary to perform calibration in daily operation. However, calibration becomes necessary after:
Motor replacement
Pulsecoder replacement
Reducer replacement
Cable replacement
Batteries for pulse count backup in the mechanical unit have gone dead
6.2. Calibrating With Special Tools
Calibrating is performed at the factory with no loads on the robot system. Based on the robot parameters and the special tools and software, this calibration method is most precise.
The data of home position may be lost due to electrical or software problems, the stored zero position can be regarded as the reference when you perform calibration by teaching method. However, this method cannot be applied to the case caused by disassembling operation or maintenance.
The following procedure guide you how to perform the home calibration by using the encoder date.
a) Jog the robot manually to the place where the calibration marks are align.
b) Watch the information on the encoder window, and then manually move the related axis in a low speed to a position where the real single loop value close to the reference value.
c) Calibrate the zero position of the axis. Create a new program, then create a new instruction “RefRobotAxis”, and run it.
6.3. Calibration in Each Axis
Calibrate the home position of J1-axis of ER3/ER6 Robot follow the procedures below.
1. Move Arm #1 to the position as shown in the figure.
2. Align the mark on Arm #1 to the mark on the base.
3. Calibrate home position again.
Calibrate the home position of J1-axis of ER20 Robot follow the procedures below.
1. Move Arm #1 to the position as shown in the figure.
2. Align the mark on Arm #1 to the mark on the base.
3. Move Arm #1 90 degrees in a counter-clockwise direction by teach pendant.
4. Calibrate home position again.