9. Device Settings

9.1 Feature Tree Introduction
After the device is connected to the client software, and you can right click the device in Device Connection, and click Feature Tree.

image.png

image.png

image.png

9.2 Code Reading Mode Settings
The device supports different code reading modes, including accurate mode and batch mode.

Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to Trigger and IO Control → Accurate Mode Enable, and enable Accurate Mode Enable.

image.png

image.png

image.png

9.3 Image Quality Settings
This section introduces how to set image related parameters of the device via client software.

image.png

9.3.1 Set Image
You can set parameters like exposure time, gain, Gamma, acquisition frame rate, acquisition burst frame count, etc. in Image Settings area.

image.png

image.png

9.3.2 Set Polling
The polling function allows the device to acquire images based on the parameters you set, including exposure time, gain, Gamma, light source, focus position, etc. Currently, two types of polling modes are available, including single mode and multiple mode.

image.png

Single Mode
Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to Image Setting → Polling Mode, and select Single as Polling Enable.
3. Select one parameter (e.g. Param1) from Polling Param.

image.png

4. Set parameters participating the polling like Polling Exposure Time, Polling Gain, Polling Gamma, etc. according to actual demands.

image.png

image.png

image.png

Multiple Mode

image.png

Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to Image Setting → Polling Mode, and select Multiple as Polling Enable.
3. Set Polling Time and Polling Period according to actual demands.
● Polling Time is used to determine whether the polling is finished or not, and it ranges from 100 to 2147482.
● Polling Period is whole period from Param1 to Param8, and it ranges from 1 to 5000.
4. Select 2 to 8 sets of parameters (e.g. Param1 and Param2) from Polling Param, and enable Polling Param Enable to let them take effect.
5. Set parameters participating the polling like Polling Exposure Time, Polling Gain, Polling Gamma, etc. according to actual demands.

image.png

6. Repeat step 4 and step 5 to set other parameters from Polling Param.
7. (Optional) View Polling Status and Best Polling Group Idx.
● Polling Status: It displays the current polling status. 0 stands for polling ended, and 1 stands for polling started.
● Best Polling Group Idx: It is used to display the polling parameter number when the device recognizes codes after enabling polling. If the polling is disabled or polling parameters are edited, it displays 1 by default. 

image.png

image.png

9.3.3 Set Light Source
Light source control allows you to enable the device’s aiming system and light source, and set related parameters according to actual demands.

image.png

Type I Device to Type VI Device
Steps
1. Go to Image Settings → Light, and enable Aiming Light Enable according to actual demands.
2. Enable Lighting Enable to enable the light source according to actual demands.
3. (Optional) Set Lighting Duration and Precharge Time if Lighting Enable is enabled.

image.png

Type VII Device
Steps
1. Go to Image Settings → Light, and select Lighting Mode according to actual demands.
2. Enable Laser Enable according to actual demands.
3. Enable Laser Delay Enable, and enter Laser Delay Duration to delay the close time of the laser after the device stops triggering.

image.png

9.3.4 Set Smart Tune
The smart tune function allows you to adjust the device’s focus position, exposure, gain, etc. by one-key operation, and supports self-adaptive adjustment.
The smart tune function has two methods to be realized, including smart tune by pressing tune button and smart tune via the client software.

Smart Tune by Pressing Tune Button

image.png

Steps
1. Go to Image Settings, click All Features on the right corner, and find Smart Tune Control.
2. Enable Button Tune, and disconnect the device from the client software.

image.png

image.png

3. Hold the tune button for 3 sec and the device starts smart tune.
● During smart tune process, the status indicator flashes in green and red colors alternatively.
● If smart tune succeeds, the status indicator is solid green lasting 3 sec and then restores.
● If smart tune fails, the status indicator is solid red lasting 3 sec and then restores.
4. (Optional) Hold the button for 3 sec again during smart tune process, and the smart tune will be cancelled.

Smart Tune via Client Software
Apart from pressing tune button to realize smart tune, you can also configure parameters via the client software to realize it.
Before You Start: Make sure that the device is not in trigger mode, and its operation mode is test.

Steps
1. Go to Image Settings, click All Features on the right corner, and find Smart Tune Control.

image.png

2. (Optional) Set Tune Timeout. If the self-adaptive adjustment exceeds configured value, and it will stop automatically.
3. Click Execute in Smart Tune Start to let the device start smart tune, and a window of smart tune will be displayed for you to view the effect.

image.png

4. (Optional) View smart tune process via Smart Tune Status.
5. Click Execute in Stop Tune to stop smart tune process.

9.3.5 Set Focus
The device supports the focus function according to the code position in the field of view. Currently, three types of focus are supported, including global auto focus, global manual focus, and ROI focus.

image.png

Global Auto Focus
The global auto focus allows you to adjust lens focus in a global field of view just by once.
Steps
1. Go to Image Settings → Smart Tune Control → Focus Param → Focus Mode Selector, and select Whole Area Focus as Focus Mode Selector.

image.png

2. Click image.png in the live view window, and click it again to stop acquisition and make sure there is an image in the window.
3. Select the focus mode in Auto Config:
● Full Auto: In this mode, the device will automatically change parameters like focus position, exposure, gain, Gamma and light source when adjusting focus.
● Motor Only: In this mode, the device will change focus position only when adjusting focus.
● Auto and Restore: In this mode, the device will automatically change parameters like focus position, exposure, gain, Gamma and light source when adjusting focus, and keep focus position and restore other parameters after completing focus adjustment.
4. Click Execute in Focus Mode, and the device starts to adjust focus automatically.

image.png

5. (Optional) Select the position parameter from Focus Position, and click Execute in Focus Position Save to save the focus position after adjusting focus.

Global Manual Focus
The global manual focus requires manual focus according to the images displayed in the live view window.
Steps
1. Go to Image Settings → Smart Tune Control → Focus Param → Focus Mode Selector, and select Whole Area Focus as Focus Mode Selector.
2. Click in the live view window, and click it again to stop acquisition and make sure there is an image in the window.
3. Select Focus Position according to actual demands and Focus Position Param.
4. Set Focus Step according to actual demands.
5. Click Execute in Focus Positive Execute and Focus Negative Execute to adjust focus position.
6. (Optional) View Focus Score to know the score of the focus adjustment.
7. (Optional) Select the position parameter from Focus Position, and click Execute in Focus Position Save to save the focus position after adjusting focus.
8. (Optional) Click Execute in Original Focus Execute to let the focus back to its original position.

ROI Focus
The ROI focus allows you to adjust lens focus regarding the ROI area by drawing specific area.

image.png

Steps
1. Go to Image Settings → Smart Tune Control → Focus Param → Focus Mode Selector, and select ROI Area Focus as Focus Mode Selector.

image.png

2. Click image.png in the live view window, and click it again to stop acquisition and make sure there is image in the window.
3. Click Draw in Draw Focus ROI, and draw ROI by dragging the mouse in live view window.

image.png

4. (Optional) Set following parameters to adjust ROI size and position.
● AF Offsex X: It is X coordinate of the upper left corner in ROI where executes auto focus.
● AF Offsex Y: It is Y coordinate of the upper left corner in ROI where executes auto focus.
● AF Width ROI: It refers to the width in ROI where executes auto focus.
● AF Height ROI: It refers to the height in ROI where executes auto focus.
5. (Optional) Click Execute in Max. Focus ROI to have a global focus.
6. (Optional) Repeat step 3 if you want to set multiple ROIs.

9.3.6 Set Self-Adaptive Adjustment
The function of self-adaptive adjustment can automatically adjust exposure, gain, Gamma and other parameters to have a better code reading effect.

image.png

Steps
1. Go to Image Settings → Smart Tune Control → Self Adapt Adjust, and unfold Self Adapt Adjust.
2. Select Adjust Source according to actual demands.

image.png

● Default Param: It adjusts the default parameters.
● Polling Param: It adjusts parameters configured in polling. After Polling Param is selected as Adjust Source, you should select a polling parameter group from Polling Param and enable or disable Focus Enable.

image.png

3. Set Exposure Max or Gain Max according to actual demands.
● Exposure Max: It sets the max. exposure during the self-adaptive adjustment.
● Gain Max: It sets the max. gain during the self-adaptive adjustment.
4. (Optional) Set self-adaptive code type in Code Type Mode.
● Code Self-Adaptive: All code types added in field of view will be self-adaptive.
● 1D Code: 1D code types added in field of view will be self-adaptive.
● 2D Code: 2D code types added in field of view will be self-adaptive.
● Stacked Code: Stacked code types added in field of view will be self-adaptive.
5. (Optional) Set light source parameters in Lighting Mode.
● Light Adapt: The client software will select the best one from all lighting options during the self-adaptive adjustment.
● Current Light Adapt: The client software will use the current configured light source.
● All Light Disable: All light sources will be turned off during self-adaptive adjustment process.
6. Click Execute in Adjust Start. The device will automatically acquire images and perform self-adaptive adjustment, and stop acquisition after adjustment is completed.

image.png

9.3.7 Set Test Pattern
Test pattern helps troubleshooting image problems and images in the test pattern are only for test. When exceptions occur in images acquired by the device in real time, you can check if images in the test pattern have similar problems to determine the cause of an exception.

image.png

Go to Image Settings, click All Features, find Test Pattern in Other Features, and set Test Pattern according to actual demands.

image.png

9.4 Code Algorithm Settings
The code reader supports reading multiple types of 1D code, 2D code, and stacked codes, and you can add and set code parameters via the client software.

9.4.1 Add Code
Adding code before you set code parameters via the client software. In Algorithm Settings, you can add different types of codes according to actual demands.
In Algorithm Settings, click Add Barcode, select types of codes to be read, and set the 1D Code Number, 2D Code Number, and Stack Bar Number according to actual demands

image.png

9.4.2 Set Code Reading ROI
Algorithm ROI (Region of Interest) allows the device to execute algorithms and read codes on the specific area you selected, and thus improving code reading efficiency.
Currently, multiple ROIs can be configured, and the device outputs codes according to the number of ROI (e.g. Region 1, Region 2, and Region 3…) in turn. The client software supports drawing single group of ROI and drawing ROI via chessboard.

image.png

Draw Single Group of ROI
Steps
1. Go to Algorithm Settings, and find Algorithm ROI.
2. Click Draw in Draw ROI to draw ROI in the live view window.

image.png

3. (Optional) Repeat the above step to draw multiple ROIs according to actual demands.

image.png

4. (Optional) Set other ROI parameters according to actual demands.
● ROI Index: It indicates different ROIs and ranges from 0 to 149 corresponds 1 to 150 ROIs.
● Algo Region Left X: It refers to the X coordinate of the upper left corner in algorithm ROI.
● Algo Region Left Y: It refers to the Y coordinate of the upper left corner in algorithm ROI.
● Algo Region Width: It refers to the width in algorithm ROI.
● Algo Region Height: It refers to the height in algorithm ROI.
5. (Optional) Click Execute in Restore Max. Algorithm ROI to restore the ROI to the full screen.
6. (Optional) Click Execute in Clear All ROI to delete all ROIs. 

Draw ROI via Chessboard
Steps
1. Go to Algorithm Settings, and find Algorithm ROI.
2. Click Execute in Chessboard ROI, set parameters, and click OK after setting.

image.png

3. Click after creating ROI, and the red frame becomes green as shown below.

image.png

4. (Optional) Click image.png to restore the ROI to full screen, and click image.pngto clean all ROIs.
5. Repeat other optional steps mentioned in drawing single group of ROI.

image.png

9.4.3 Set Algorithm Parameter

In Algorithm Parameter, select 1DCode, 2DCode or Stacked Code as Arithmetic Type, and then you can set its corresponding parameters.

image.png

Set 1D Code
● Timeout Value: Timeout value refers to the maximum running time of algorithm, and its unit is ms. The code reader will stop parsing the images and return results if the time is exceeded the waiting time configured.
● Code Color: It defines the readable code color. White Code On Black Wall means that the client software can recognize the white code with black background. Black Code On White Wall means that the client software can recognize the black code with white background. Adaptive means that the client software can recognize both the black code with white background, and the white code with black background.
● Code 39 Check: Enable this parameter if Code 39 uses the parity bit.

image.png

● ITF 25 Check: Enable this parameter if ITF 25 uses the parity bit

image.png

● 1D Code Quality Enable: If it is enabled, the client software will judge the quality of 1D code and output overall grade. Currently, this parameter is only applicable to Code 39 and Code 128.
● Code Score Enable: If it is enabled, the client software will evaluate the code reading environment for 1D code and output code score.

Set 2D Code
● Timeout Value: Timeout value refers to the maximum running time of algorithm, and its unit is ms. The code reader will stop parsing the images and return results if the time is exceeded the waiting time configured.
● Algorithm Running Mode: It is used to be set the algorithm operating mode. It includes High Speed, High Performance, and Balance. High Speed focuses on recognition speed, and the algorithm can recognize the code rapidly, while High Performance refers to the algorithm can recognize the code that has distortion, spot or white gap, but its recognition speed is slow. Balance refers to the algorithm makes a balance between speed and performance.
● 2D Code Max. Size: It refers to the max. recognizable code width. The 2D code will not be recognized if its width exceeds the configured value.
● Mirror Mode: It is useful when the recognized image is a mirror one, mirroring in X coordinate. 3 modes are available: Adaptive, Mirror, and Non Mirror.
● Downsampling Level: It refers to the pixel sample size that the code reader takes. Increasing this parameter will improve the code reading efficiency at the expense of code recognition rate.

image.pngimage.png

● Code Color: It defines the readable code color. Adaptive means that the client software can recognize both the black code with white background, and the white code with black background. White Code On Black Wall means that the client software can recognize the white code with black background. Black Code On White Wall means that the client software can recognize the black code with white background.

image.png

image.png

● Discrete Flag: Continuous stands for the minimum units in the "L" shaped sides of the DM code are continuous, or the minimum units in the concentric square like image.png or image.png in the QR code are continuous. Usually the continuous code uses squares as the minimum units. Discrete stands for the minimum units in the "L" shaped sides of the DM code are discrete, or the minimum units in the concentric square likeimage.png orimage.png in the QR code are discrete. Usually the discrete code uses dots as the minimum units.
Adaptive stands for the device can recognize both continuous code and the discrete code.
● QR Distortion Correction: If the QR code or DM code is distorted, you can enable this parameter to improve code recognition rate.

image.png

● DM Code Shape: It defines the recognizable code shape. Square stands for square mode:
If the 2D code is square shaped, it can be recognized by the device. Rectangle stands for rectangle mode: If the 2D code is rectangle shaped, it can be recognized by the device.
Adaptive stands for compatible mode: The device can recognize 2D codes of both the above-mentioned two shapes.
● DM Code Type: It includes All, ECC140, and ECC200.
● 2D Code Quality Enable: Refer to section Set 2D Code Quality Evaluation for details.
● Code Score Enable: If it is enabled, the device will evaluate code quality and display overall grade and code score in history record area of the client software. The higher the score, and the better the code quality.
● Accurate Timeout Enable: If it is enabled, the accuracy of algorithm timeout will improve.

Set Stacked Code
Code Score Enable: If it is enabled, the client software will evaluate the code reading environment for stacked code and output code score.

9.4.4 Set Code Quality Evaluation
The code quality evaluation function judges the quality of codes and outputs overall grade. Currently, only 1D code and 2D code support code quality evaluation.

image.png

Set 1D Code Quality Evaluation
The 1D quality evaluation function uses the ISO15416 standard to judges the quality of codes and outputs overall grade. Currently, this function is only applicable to Code 39 and Code 128.
Steps
1. Go to Algorithm Control → Algorithm Parameter, and select 1D Code as Arithmetic Type.
2. Enable 1D Code Quality Evaluation.
3. Enable different quality evaluation standards according to actual demands.

image.png

image.png

4. Set the evaluation value for A/B/C/D grade according to actual demands.

image.png

5. Enable Aperture Enable and enter Aperture according to the smallest size of codes.
6. (Optional) Set Quality 1D Max Num to configure the amount of code to be evaluated. If the actual amount of code exceeds the configured, the later codes will not be evaluated.
7. (Optional) Go to Algorithm Control → Rating Standard 1D Enable, set enable Rating Standard 1D Enable, and select 1D Rating Standard.

image.png

7. Click image.png to start acquisition, and the client software will display the overall code quality in the history record area.

image.png

 

Set 2D Code Quality Evaluation
The 2D quality evaluation function uses the ISO15415 standard to judges the quality of codes and outputs overall grade.

image.png

Steps
1. Go to Algorithm Control → Algorithm Parameter, and select 2D Code as Arithmetic Type.
2. Enable 2D Code Quality Evaluation.
3. Set Iso Edition, including Iso15415 and Iso29158
● Iso15415 is applicable to the quality evaluation for label 2-dimensional codes.
● Iso29158 is applicable to the quality evaluation for DPM format 2-dimensional codes.
4. Refer to step 5 to step 7 in Set 1D Code Quality Evaluation to set other parameters.

9.4.5 Set Code Score
The code score function evaluates the code-reading environment for codes and outputs code score.

image.png

Steps
1. Go to Algorithm Settings, and enable Code Score Enable.

image.png

2. Click image.png to start acquisition, and the client software will display specific code score in the history record area.

image.png

3. (Optional) Go to Image Settings, and adjust parameters like exposure time, gain, Gamma, light source, etc. if the code score is low. 

image.png

9.5 Line Mode Settings
Line mode settings allow you to customize the specific line as input or output according to actual demands.
Go to I/O Control Settings → Line Mode Control, and set Input or Output according to actual demands.

image.png

image.png

 

9.6 Signal Input Settings

In the signal input module, you can set the trigger related parameters. You can enable trigger mode to let the acquisition of image data occur only when the trigger source is generated.

9.6.1 Set Trigger Mode
The device has 2 types of trigger mode: Internal trigger mode and external trigger mode.
● Internal Trigger Mode: The device acquires images via its internal signals.
● External Trigger Mode: The device acquires images via external signals like software signal and hardware signal. The trigger source of external trigger mode includes software, physical lines, counter, TCP, UDP, etc.

image.png

 

9.6.2 Enable Internal Trigger Mode
In the internal trigger mode, the device acquires images via its internal signals. You have 2 methods to enable the internal trigger mode:
● Click I/O Control Settings → Input → Trigger Mode, and select Off as Trigger Mode.
● In the live view page, click  image.png to enable the internal trigger mode.

9.6.3 Enable External Trigger Mode
In the external trigger mode, the device acquires images via external signals like software signal and hardware signal. You have 2 methods to enable the external trigger mode:
● Click I/O Control Settings → Input → Trigger Mode, and select On as Trigger Mode.
● In the live view page, click image.pngto enable the external trigger mode.

Set and Execute Software Trigger Mode
In software trigger, the software sends trigger signal to the device via I/O interface to acquire images.

Steps
1. Click I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select Software as Trigger Source.
4. Click Execute in Trigger Source to send trigger commands.
You can also enter Auto Trigger Time, and then enable Enable Auto Trigger to let the client software automatically send trigger signal to device according to the interval you set.

image.png

 

Set and Execute Hardware Trigger Mode
Steps
1. Click I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select the specific line as Trigger Source according to actual demands.

image.png

4. Set Debounce Time and Line Out Trigger In Polarity according to actual demands.

image.png

image.png

 

Set and Execute Counter Trigger Mode
Counter specifies that the trigger source will be generated after the set number of valid signals appears. For example, if you set the Count Number to 3, the trigger source will be generated after 3 signals appear.
Steps
1. Click I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select Counter 0 as Trigger Source.
4. Set Trigger Delay, Count Number, Count Source and Line Out Trigger In Polarity according to actual demands.

image.png

 

Set and Execute TCP Trigger Mode
TCP start specifies the TCP server as the source for the trigger signal. When the server receives the specified string text, the trigger signal will be outputted.
Steps
1. Go to I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select TCP Start as Trigger Source.
4. Set following parameters according to actual demands.
● TCP Trigger Port: It sets the host port of TCP trigger.
● TCP Start Trigger Text: It sets the trigger text of TCP start, and it is Start by default.

Set and Execute UDP Trigger Mode
UDP start specifies the UDP server as the source for the trigger signal. When the server receives the specified string text, the trigger signal will be outputted.

Steps
1. Go to I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select UDP Start as Trigger Source.
4. Set following parameters according to actual demands.
● UDP Trigger Port: It sets the host port of UDP trigger.
● UDP Start Trigger Text: It sets the trigger text of UDP start, and it is Start by default.
Set and Execute Serial Port Trigger Mode
Serial start specifies the serial port as the source for the trigger signal. When the serial port receives the specified string text, the trigger signal will be outputted.

Steps
1. Go to I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select Serial Start as Trigger Source.
4. Set Serial Baudrate, Serial Data Bits, Serial Parity, and Serial Stop Bits.
5. Set Serial Start Trigger Text that configures the trigger text of serial port start, and it is Start by default. 

Set and Execute USB Trigger Mode
Steps
1. Go to I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select USB Start as Trigger Source.
4. Set USB Baudrate, USB Data Bits, USB Parity, USB Stop Bits, and USB Start Trigger Text according to actual demands.

Set and Execute Self Trigger Mode
Self trigger allows you to trigger the device according to the trigger period you configured.
Steps
1. Click I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select Self Trigger as Trigger Source, set Self Trigger Period and Self Trigger Count.

image.png

image.png

Set and Execute Response Tigger
Steps
1. Click I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select Response Trigger as Trigger Source, and set Trigger Sensitivity accordingly.

9.6.4 Stop Trigger
The device supports stopping trigger via TCP, UDP, I/O, serial port and USB. You can also set code reading timeout duration or max. code amount to be read to stop trigger. After stopping trigger is completed, the device cannot make response to trigger again.

image.png

image.png

 

Stop Trigger via TCP
When the TCP server receives the specified string text, the trigger will be stopped.
Steps
1. Go to I/O Control Settings → Stop Trigger.
2. Enable TCP Stop Trigger Enable.
3. Set following parameters according to actual demands.
● TCP Trigger Port: It is 2001 by default.
● TCP Stop Trigger Format: It is Str by default.
● TCP Stop Trigger Text: It sets the stop trigger text, and it is Stop by default.

Stop Trigger via UDP
When the UDP receives the specified string text, the trigger will be stopped.
Steps
1. Go to I/O Control Settings → Stop Trigger.
2. Enable UDP Stop Trigger Enable.
3. Set following parameters according to actual demands.
● UDP Trigger Port: It is 2002 by default.
● UDP Stop Trigger Format: It is Str by default.
● UDP Stop Trigger Text: It sets the stop trigger text, and it is Stop by default.
Stop Trigger via IO
Stopping trigger via IO allows you to select hardware or software trigger source to stop the device from acquiring images.
Steps
1. Go to I/O Control Settings → Stop Trigger.
2. Enable IO Stop Trigger Enable.
3. Select sources from LineIn 0/1/2/3 and Software Trigger End as IO Stop Trigger Selector.
4. (Optional) Set trigger activation if LineIn 0/1/2/3 is selected as IO Stop Trigger Selector.
5. (Optional) Click Execute in Software Stop Trigger to stop trigger if Software Trigger End is selected as IO Stop Trigger Selector.

Stop Trigger via Serial Port
When the specified serial port receives the specified string text, the trigger will be stopped.
Steps
1. Go to I/O Control Settings → Stop Trigger.
2. Enable Serial Stop Trigger Enable.
3. Set following parameters according to actual demands.
● Serial Stop Trigger Text: It sets the trigger text of serial port stop, and it is Stop by default.
● Serial Baud Rate: It sets the baud rate of the serial port, and it is 9600 by default.
● Serial Data Bits: It sets the data bits of the serial port, and it is 8 by default.
● Serial Parity: It sets the parity of the serial port, and it is No Parity by default.
● Serial Stop Bits: It sets the stop bits of the serial port, and it is 1 by default.

Stop Trigger via USB
The USB stop trigger function means that the device receives USB commands from the external device to stop image acquisition. At this time, the device acts as a USB server to receive commands, and the external device communicating with it acts as a USB client to send commands.
Go to Feature Tree, find Stop Trigger Control, enable USB Stop Trigger Enable, set USB Stop Trigger Text, USB Baudrate, USB Data Bits, USB Parity, and USB Stop Bits according to actual demands.

image.png

 

Stop Trigger via Timeout Duration
When the trigger time reaches the specified maximum value (ms), the trigger will be stopped. You can enable TimeOut Stop Trigger Enable, and set Maximum Output Limited Time according to actual demands.

image.png

image.png

 

Stop Trigger via Code Number
This function means that the code quantity outputted by the device is restricted to the settings you configured here.
You can enable CodeNum Stop Trigger Enable, and set CodeNum Stop Trigger Min and CodeNum Stop Trigger Max according to actual demands.

image.png

image.png

 

9.7 Signal Output Settings
9.7.1 Select Output Signal
The device’s output signal can control external devices like PLC, flashing light, etc. Click I/O Control Settings → Output → Line Out Selector to select output signal.

image.png

image.png

9.7.2 Enable Line Inverter
The line inverter function allows the device to invert the electrical signal level of an I/O line, and meets requirements of different devices for high or low electrical signal level.
You can go to I/O Control Settings → Output → Line Out Inverter to enable it.

image.png

image.png

 

9.7.3 Set Event Source
The device supports outputting different trigger signals according to the event source you select. Click I/O Control Settings → Output → Line Out Activation Event to select event source.
The device supports following event sources, including Off, NoCodeRead, ReadSuccess, Compare Success, and Compare Fail.

image.png

● No Code Read: If no code read by the device, the output signal will be triggered.
● Read Success: If the code is read by the device, the output signal will be triggered.
● Compare Success: If data comparison is successful, the output signal will be triggered.
● Compare Fail: If data comparison is failed, the output signal will be triggered.
● Command Control IO: It is controlled by the communication strings.

image.png

Select No Code Read
If you select No Code Read as Line Out Activation Event, and you can set its output delay time and duration.
● Line Out Delay Time: It sets the delay time for outputting the output signal.
● Line Out Duration: It sets the time duration of the output signal.

image.png

Select Read Success
If you select Read Success as Line Out Activation Event, and you can set its output delay time and duration.
● Line Out Delay Time: It sets the delay time for outputting the output signal.
● Line Out Duration: It sets the time duration of the output signal.

image.png

 

Select Compare Success
If you select Compare Success as Line Out Activation Event, and you can set its output delay time and duration.
● Line Out Delay Time: It sets the delay time for outputting the output signal.
● Line Out Duration: It sets the time duration of the output signal.

image.png

 

Select Compare Fail
If you select Compare Fail as Line Out Activation Event, and you can set its output delay time and duration.
● Line Out Delay Time: It sets the delay time for outputting the output signal.
● Line Out Duration: It sets the time duration of the output signal.

image.png

 

Select Command Control IO
If you select Command Control IO as Line Out Activation Event, and you do not need to set any parameters.
● Control Start Str: It sets the start string of command control.
● Control Stop Str: It sets the stop string of command control.
● Line Out Delay Time: It sets the delay time for outputting the output signal.
● Line Out Duration: It sets the time duration of the output signal.

image.png

 

9.7.4 Set Buzzer

image.png

The buzzer is used to indicate the device’s operation status, and you can set the buzzer function according to actual demands.

Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to Trigger and IO Control→ Buzzer Enable, and enable Buzzer Enable.

image.png

3. Set Buzzer Duration (ms) and Buzzer Frequency (hz) according to actual demands.

image.png

9.8 Communication Settings
The communication protocol is used to transmit and output code reading result and image. The communication protocol is related to the device modes. With various device modes, the device supports different communication protocols and corresponding parameters.
● If the device’s operation mode is Test or Raw, and it only supports SmartSDK protocol and no parameter settings are required.
● If the device’s operation mode is Normal, and it supports SmartSDK, TCP Client, Serial, FTP, TCP Server, Profinet, MELSEC/SLMP, Ethernet/IP, ModBus, UDP, Fins and USB communication protocols, and you need to set corresponding parameters.

image.png

 

9.8.1 Set SmartSDK
If you select SmartSDK as the communication protocol, you can configure the following parameters:

image.png

 

9.8.2 Set TCP Client
If you select TCP Client as the communication protocol, you can configure the following parameters: 

image.png

 

9.8.3 Set Serial
If you select Serial as the communication protocol, you can configure the following parameters:

image.png

 

9.8.4 Set FTP
If you select FTP as the communication protocol, you can configure the following parameters:

image.png

 

9.8.5 Set TCP Server
If you select TCP Server as the communication protocol, you can configure the following parameters:

image.png

 

9.8.6 Set Profinet
If you select Profinet as the communication protocol, you can configure the following parameters:

image.png

 

9.8.7 Set MELSEC/SLMP
If you select Melsec/SLMP as the communication protocol, you can configure the following parameters:

image.png

 

9.8.8 Set Ethernet/IP
If you select EthernetIp as the communication protocol, you can configure the following parameters:

image.png

9.8.9 Set ModBus
If you select Modbus as the communication protocol, you can configure the following parameters:

image.png

 

9.8.10 UDP
If you select UDP as the communication protocol, you can configure the following parameters:

image.png

 

9.8.11 Fins
If you select Fins as the communication protocol, you can configure the following parameters:

image.png

 

9.8.12 USB
If you select USB as the communication protocol, you can configure the following parameters:

image.png

 

9.9 Data Processing Settings
In Data Processing, you can set filter rules for reading codes and other data processing related parameters.

image.png

 

9.9.1 Set Filter Rule
You can set rules via Filter Rule to filter unwanted codes to improve the reading efficiency.

 

Normal Filter Mode
If the device’s operation mode is normal, trigger mode is on, filter mode is normal, and you
can set following parameters according to actual demands:
● Instant Output Mode Enable: If enabled, the device will output barcode data immediately
once a code is read. If not enabled, the barcode data will be outputted after the device
trigger process ends.

image.png

● Min. Output Time(ms) : Define the minimum time duration (unit: ms) for data output. The duration starts from trigger time. Note: The parameter is only available when the running mode is set to Normal mode and the trigger mode is enabled.

image.png

● Min. Code Length: If the length of a barcode is shorter (in terms of the number of characters) than the configured value, the device will NOT parse the barcode.
For example, if you set the value to 6, the device will not parse the barcodes which contain fewer than 6 characters.

image.png

● Max. Code Length: If the length of a barcode is longer (in terms of the number of characters) than the configured value, the device will NOT parse the barcode.
For example, if you set the value to 9, the device will not parse the barcodes which contain more than 9 characters.

image.png

● Numeral Filter: If enabled, the device will only parse and read the numeral contents of the barcodes, and the non-numeral contents will be filtered out.
● Begin with Specific Character for Result: enabled, the device will only read the barcodes which begin with a specific character string.
● Begins with: Enter the character string.
● Include Specific Character in Barcode: If enabled, the device will only read the barcodes which include a specific character string.
● Character: Enter the character string.
● Exclude Specific Character in Barcode: If enabled, the device will only read the barcodes without a specific character string.
● Character: Enter the character string.
● Remove Duplicate By ROI: If it is enabled, the device will filter information based on drawn ROIs.
● Read Times Threshold: If the reading results of a barcode is same for the configured times, the barcode will be regarded as valid and its data will be outputted. Or the barcode will be regarded as invalid and its data will not be outputted.
● De-duplication Enable By Trigger: If it is enabled, the repeated code information will be filtered within specific trigger times. You can set trigger times in De-duplication Windows Size, and its default value is 1.
● De-duplication By ROI: If it is enabled, the device will filter information based on drawn ROIs.
● Code Start Offset Num: It cuts the specific length of code contents from starting, and the remaining part will be outputted.
● Code End Offset Num: It cuts the specific length of code contents from ending, and the  remaining part will be outputted.

Regular Expression Filter Mode
The device supports filtering codes via the regular expression.
Steps
1. Select Regular Expression as the Filter Mode, and click Set in Regular Expression Filter to enter regular expression filter settings window.
2. Import local files or add customized filter rules to set the regular expression.
● Import local files: Click Import to import local .xml files, and click OK to finish.

image.png

● Add customized filter rule: Click Add and set related parameters in the popped-up window, and click OK after configuring parameters.

image.png

image.png

3. After setting filter rule, enter the code in Code Check to check if the filter rule is successful.

image.png

image.png

4. (Optional) Click image.png to delete unwanted filter rules.
5. (Optional) Click Export to export configured filter rules to local PC

image.png

 

9.9.2 Data Processing Settings
You can configure the contents contained in the output barcode information.

image.png

SmartSDK
● NoRead Image Index: It sets the specific image that is outputted when no code information is read. For example, if you set this parameter as 5, and the 5th image will be output.
● One By One Enable: If it is enabled, the device will send one piece of code information each time in accordance with the specified interval. You can set the interval via One By One Interval and the default value 100 ms.

FTP
When the communication protocol is FTP, set the following parameters of data processing:
● NoRead Image Index: It sets the specific image that is outputted when no code information is read. For example, if you set this parameter as 5, and the 5th image will be output.
● One By One Enable: If it is enabled, the device will send one piece of code information each time in accordance with the specified interval. You can set the interval via One By One Interval and the default value 100 ms.
● Local Save Picture Mode: It includes Off, NoRead, and Insufficient Code. You can select NoRead to let the device save images when no code is read.
● Local Picture Type: Specify the type of pictures saved locally. You can select JPEG or BMP.
● Output Retrans Enable: Enable to allow data re-transmission. Specify the limit of retransmission attempts in Output Retrans Number.
● FTP Picture Name Format: Click image.pngto select one or multiple items to be contained in the picture name. The selected items will be displayed in the frame. You can also enter more contents directly in the frame.
● FTP Transmission Conditions: Set the condition to upload the data outputted by the device to FTP server.
○ All: Always upload the data.
○ ReadBarcode: Upload the data only when the barcode is read by the device.
○ NoReadBarcode: Upload the data only when no barcode is read by the device.
● FTP Transmission Result Contain: Select contents to upload to the FTP server.
○ JustResult: Only upload the content of the barcode.
○ JustPicture: Only upload the barcode image.
○ ResultAndPicture: Upload both the content of the barcode and the barcode image.
● FTP Time Format: Select a format type from the drop-down list for the time stamp contained in the file name.

image.png

 

TCP Client / Serial / TCP Server / Profinet / MELSEC / EthernetIp / Modbus / UDP / FINS/ USB

When the communication protocol is TCP Client / Serial / TCP Server / Profinet / MELSEC / EthernetIp / Modbus / UDP / FINS/ USB, set the following parameters of data processing.

image.png

● NoRead Image Index: It sets the specific image that is outputted when no code information is read. For example, if you set this parameter as 5, and the 5th image will be output.
● One By One Enable: If it is enabled, the device will send one piece of code information each time in accordance with the specified interval. You can set the interval via One By One Interval and the default value 100 ms.
● Local Save Picture Mode: It includes Off, NoRead, and Insufficient Code. You can select NoRead to let the device save images when no code is read.
● *** Output Format: Click image.png to select one or multiple items to be contained in the picture name. The selected items will be displayed in the frame. You can also enter more contents directly in the frame.

● *** Output Noread Enable: Enable this to set the default output content if no barcode is read during transmission. Edit the output text in Output NoRead Text.
● *** Output Start Text: The contents of the start part of the data outputted. You can set the contents as desired.
● *** Output Stop Text: The contents of the end part of the data outputted. You can set the contents as desired.
● *** Output Barcode Enter Character Enable: Whether to show input character in the data.
● *** Output Barcode Newline Character Enable: Whether to show new-line character in the data.

9.10 Set Multicast
The multicast function is used to let multiple devices have the same trigger number when they are acquiring images and analyzing codes at the same time. When each device sends the trigger number and outputted images to the code reading platform, the platform will integrate the images with the same trigger number as the information of the same package. The main principle of the multicast function is to set one main device among multiple devices, and remaining devices are called sub devices. As the first triggered device, the main device sends trigger numbers to sub devices each time, and sub devices replace their trigger numbers with received ones so that all devices have the same trigger numbers.
Follow the steps below to set multicast function according to actual demands.

Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to Multi Camera Control, set one device as Main in Multi Camera Mode according to actual demands.

image.png

image.png

3. Set GroupID.

image.png

 

9.11 Main-Sub Networking
When multiple devices acquire images and parse codes at the same time, the main-sub networking function enables multiple devices to work together.
The main principle of main-sub networking is to set one of the multiple devices as the main device (main station), and the other devices as sub devices (sub station). The sub devices send the code results to the main device that integrates or forwards, and sends the code results to the connected PC or client software to realize the collaborative work function of multiple devices.

Before You Start
Make sure that the device mode is Normal and Tigger Mode is On before using this function.

image.png

Steps
1. Go to Multi Camera Control, and select Multi Station Work Mode according to actual demands.
● Off: This function is disabled.
● Independent: The main device and the sub devices are triggered respectively, and the sub devices send the code reading result to the main device. The main device directly formats and outputs the sub devices’ data according to the formatting rules without data processing. It is mainly used for the scenario of multiple assembly lines.
● Cooperation: The main device and the sub devices use the same trigger, the sub devices send the code reading result to the main device for data processing, and then format and output the data after the fusion of the main and sub devices according to the formatting rules. It is mainly used to the scenario where the field of view is insufficient, and multiple codes are read together to integrate the output. In most cases, this mode is used.
2. Set role for different devices in Station Role. Main is the main device, and Sub is the sub device

image.png

3. Set Station Port to configure the main station’s port number and communicate with the sub station.
4. (Optional) Enable Client Display Sub Enable to let the main device display the code reading images from the sub station.

image.png

5. Set MS Group ID ranging from 100 to 200 to configure the main-sub networking group ID.

image.png

6. (Optional) View enumerated sub station quantity via Sub Station Total as a main station role.
7. (Optional) View sub station information after entering Query Sub Station ID as a main station role.
● Sub Station IP: The IP information of the sub station.
● Sub Station Connect: The connection status of the sub station. 1 stands for normal data transmission. Otherwise, it is disconnected.
● Sub Station UN: The user name information of the sub station.
● Sub Station MN: The product model information of the sub station.
● Sub Station SN: The serial number of the sub station.
8. (Optional) View main station information when the Station Role is Sub.
● Main Station IP: The IP information of the main station.
● Main Station Connect: The connection status of the main station. 1 stands for normal data transmission. Otherwise, it is disconnected.
● Main Station UN: The user name information of the main station.
● Main Station MN: The product model information of the main station.
● Main Station SN: The serial number of the main station.

image.png

 

9.12 Contrast Control Settings

image.png

The contrast control function compares the data that the device reads with preset data and outputs contrast result. The result can be used as the event source of trigger signal, including Contrast Success and Contrast Fail. This function has two ways to contrast, including regular contrast and consecutive number contrast.

Regular Contrast
The regular contrast requires you to set code contents in advance, and the client software will contrast the data that the device reads with preset contents and outputs comparison result.
Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to Contrast Control, enable Contrast Enable, and select Regular as Contrast Rules.
3. Set Start Position that means the stating position of the comparison.
4. Set Character Number that means the comparison quantity.
5. Set code contents in Wildcard String. 

image.png

image.png

 

Consecutive Number Contrast
The consecutive number contrast requires you to set consecutive code rules, and the client software will contrast the data that the device reads with preset rules and outputs contrast result.
Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to Contrast Control, enable Contrast Enable, and select Consecutive Number as Compare Rules.
3. Set Start Position that means the stating position of the comparison.
4. Set Digital Number that means the comparison quantity.
5. Set Step that means the client software will increase or decrease the preset value after each comparison according the step you set.

image.png

6. (Optional) Click Execute in Contrast Reset to reset comparison. After that, the client software will use the first code it reads as the preset value.
Here we take start position (3), digital number (2) and step (2) as an example to explain the consecutive number comparison:
● If the first code that the device reads is ur96k, and then the preset value is 96. The preset value increases to 98 (96+2).
● If the second code is yr98kjkfd, and comparison succeeds. The preset value increases to 100 (98+2).
● If the third code is kl99fjkd, and comparison fails. The preset value does not increase.
● If the fourth code is kl00djf, and comparison succeeds. The preset value increases to 02 (00+2).

image.png

 

9.13 Statistics Information
The statistics information in the feature tree helps you to count data related with code reading.

image.png

Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to feature tree, find Statistics Info., and select Statistics Mode:
● All Frames means the client software will display all data since the device is powered on.
● Latest Frames means the client software will display data of the last 10 frames.
3. View related parameters.
4. (Optional) Click Execute in Reset Statistics to reset statistics information.

image.png

image.png

image.png

 

9.14 Diagnose Event Report
The diagnose event report function monitors memory and CPU usage rate, and let you know when there is a crash, higher CPU usage rate, insufficient memory, and other events.
Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to feature tree, find Diagnose Event Report.
3. View relation information.
4. (Optional) Click Execute in Reset Event to clear all information.

image.png

 

9.15 User Set Customization
In Configuration Management, you can set and manage the user set. A user set is a group of parameter values with all the settings needed to control the device, and you can save, load and switch different user sets.
● Save Settings: If you have set the device parameters as desired, you can save them into the user set. Go to Config Management → Save Settings, and click UserSet1, UserSet2, or UserSet3 to save the current device settings.
● Load Settings: You can load the user set to restore the device to the saved group of parameter values again if required. Go to Config Management → Load Settings, and click Default, UserSet1, UserSet2, or UserSet3 to load settings.

image.png

● Start Settings: The selected user set will be automatically loaded after the device being powered on. For example, if you select Default, the device parameter settings will be restored to the factory settings.

image.png