5. Function Parameter List
The function parameters of KE300 series inverter have been divided into 19 groups including P0~PP, A0, U0 according to the function. Each function group contains certain function codes. For example, “P1-10” means the tenth function code in the P1 function group. P0~PE are basic function parameter groups; PF is factory parameter group (users are forbidden to access); A0 is torque control function parameter group; U0 is monitor function parameter group.
If PP-00 is set to non-zero value, it means parameter protection password is set, and the parameter menu cannot be entered until correct password is input. To cancel the password, please set PP-00 to “0”.
A0 and U0 are default hidden parameter groups, which can be displayed by modifying PP-02.
The instruction of the symbols in function parameter list is as following:
“○”:means that the parameter setting value can be modified on stop and running status.
“◎”:means that the parameter setting value cannot be modified on the running status.
“●”:means that the value of the parameter is the real detection value which cannot be modified.
5.1 Basic Function Parameter Table