4. Basic Settings
You can implement the functions of parameter setting, display, monitoring, alarm, adjustment, etc. of the Drive in the following two ways.
Use the Panel Operator of the Drive
Use the Motion Perfect V5.3 or above (Recommended)
4.1 Panel Operator
4.1.1 Key Names and Functions
There is a Panel Operator on the front of the Drive, as is shown in Figure 4-1.
The names and functions of the keys on the Panel Operator are as follows.
4.1.2 Basic Mode Selection
The basic modes include Status Display Mode, Parameter Setting Mode, Utility Function Mode, and Monitor Mode. Select a basic mode with [M] key to display the operation status, set parameters and operation references, as is shown in Figure 4-2.
4.1.3 Status Display Mode
Power ON the Drive and wait for a while, the Panel Operator will initially display the Servo Status.
The information displayed by the status is divided into two parts:
The first two digits are called Bit Data, what indicates the signal states during the operation of Drive.
The last three digits are called Code, what indicates the operation states of Drive.
The display meaning of each segment on Bit Data are shown in Table 4-1, and they have different meanings under Speed or Torque Control Mode and Position Control Mode.
The display meanings of Code are shown in Table 4-2
4.1.4 Parameter Setting Mode
Functions can be selected or adjusted by setting parameters. There are two types of parameters.
Function Parameters: the functions allocated to each digit of the Panel Operator can be selected.
Adjustment Parameters: a parameter is set to a value within the specified range of the parameter.
For a description of the parameter settings, please refer to the section Chapter 12 Parameters.
Function Parameters Setting
The example below shows how to change parameter Pn003 (Application Function Selections 3) from 0000 to 1032.
Step 1 Press [M] key several times to select the Parameter Setting Mode.
Step 2 Press [▲] key or [▼] key to select the parameter Pn003.
Step 3 Press [◄] key to display the current value of Pn003.
Step 4 Press and hold [◄] key for 1 second or more, and then a flashing decimal point will appear at the bottom right of the 5th digit.
Step 5 Press [▲] key twice, changing the value of the 5th digit from 0 to 2.
Step 6 Press [◄] key once, moving the flashing decimal point to the 4th digit.
Step 7 Press [▲] key three times, changing the value of the 4th digit from 0 to 3
Step 8 Press [◄] key twice, moving the flashing decimal point to the 2nd digit.
Step 9 Press [▲] key once, changing the value of the 2nd digit from 0 to 1.
Step 10 Press and hold [◄] key for 1 second or more to return to the display of the Pn003 parameter value or press the [M] key to return to the display of the Pn003.
----End
Adjustment Parameters Setting
The example below shows how to change parameter Pn102 (Speed Loop Gain) from 100 to 85.
Step 1 Press [M] key several times to select the Parameter Setting Mode.
Step 2 Press [▲] key or [▼] key to select the parameter Pn102
Step 3 Press [◄] key to display the current value of Pn102.
Step 4 Press [▲] key or [▼] key to change the value to 00085.
Press and hold [▲] key or [▼] key to jump the setting value quickly.
Step 5 Press [◄] key or [M] key to return to the display of Pn102.
----End
The example below shows how to change parameter Pn504 (Deviation Counter Overflow Alarm) from 41943040 to 42943240.
Step 1 Press [M] key several times to select the Parameter Setting Mode.
Step 2 Press [▲] key or [▼] key to select the parameter Pn504
Step 3 Press [◄] key to display bottom four digits of the current value of Pn504.
Step 4 Press and hold [◄] key for 1 second or more, and then a flashing decimal point will appear at the bottom right of the 5th digit.
Step 5 Press [◄] key twice, moving the flashing decimal point to the 3rd digit.
Step 6 Press [▲] key twice, changing the value of the 3rd digit from 0 to 2.
Step 7 Press [◄] key four times, moving the flashing decimal point to the 3rd of middle four digits.
Step 8 Press [▲] key once, changing the value of the 3rd digit from 1 to 2.
Step 9 Press and hold [◄] key for 1 second or more to return to the display of the Pn504 parameter value or 8press the [M] key to return to the display of the Pn504.
----End
4.1.5 Monitor Mode
The Monitor Mode can be used for monitoring the reference values, I/O signal status, and Drive internal status.
The Monitor Mode can be selected during Motor operation.
Select Monitor Mode
The example below shows how to display, the contents of monitor number Un003 (when the Motor rotates at 100).
Step 1 Press [M] key several times to select the Monitor Mode.
Step 2 Press [▲] key or [▼] key to select the monitor number Un003.
Step 3 Press [◄] key to display the data of Un003.
Step 4 Press [◄] key to return to the display of Un003.
----End
Contents of Monitor Mode Display
The status (low level or high level) of input signal allocated to each input terminal is displayed
4.1.6 Utility Function Mode
This section describes how to apply the basic operations using the Panel Operator to run and adjust the Motor.
The following table shows the parameters in the Utility Function Mode.
Fn000 (Alarm trace data display)
The alarm trace data display can display up to ten previously occurred alarms. The following are the steps to display the alarm trace data.
Step 1 Press [M] key several times to select the Utility Function Mode.
Step 2 Press [▲] key or [▼] key to select the function number Fn000.
Step 3 Press [◄] key to display latest alarm number.
Step 4 Press [▲] key or [▼] key to view the other alarm data.
Step 5 Press the [◄] key to return to the display of the Fn000.
Press and hold [◄] key for 1 second or more to clear all the alarm trace data.
----End
Fn001 (Initialize parameter settings)
The following are the steps to initialize parameter settings.
Step 1 Press [M] key several times to select the Utility Function Mode.
Step 2 Press [▲] key or [▼] key to select the function number Fn001.
Step 3 Press [◄] key, and Panel Operator displays as below.
Step 4 Press and hold [◄] key for 1 second to initialize the parameter settings, until Panel Operator displays and blinks done, which indicates the initialization of parameter setting has been completed.
Step 5 Release [◄] key to return to the display of the Fn001.
----End
Fn002 (JOG operation)
This utility function often used for trial operation, refers to the section 9.3.3 JOG Operation.
Fn005 (Automatic offset-adjustment of Motor current detection signal)
Motor current detection offset adjustment has been performed before shipping. The user need not perform this adjustment.
The following are the steps to execute the automatic offset adjustment.
Step 1 Press [M] key several times to select the Utility Function Mode.
Step 2 Press [▲] key or [▼] key to select the function number Fn005.
Step 3 Press [◄] key, and Panel Operator displays as below.
Step 4 Press [M] key to execute the automatic offset adjustment.
Panel Operator displays and blinks done, and 2 seconds later, it will return to previous display.
Step 5 Press the [◄] key to return to the display of the Fn005.
----End
Fn006 (Manual offset-adjustment of Motor current detection signal)
To adjust the offset, perform the automatic adjustment (Fn005) first. And if the torque ripple is still big after the automatic adjustment, perform the manual offset-adjustment as follow.
Step 1 Press [M] key several times to select the Utility Function Mode.
Step 2 Press [▲] key or [▼] key to select the function number Fn006.
Step 3 Press [◄] key, and Panel Operator displays as below.
Step 4 Press [M] key for switching the display between 0_CuA (phase-U) and 1_Cub (phase-V).
Step 5 Select one phase display (e.g., 1_Cub, phase-V), and press and hold [◄] key for 1 second or more, Panel Operator will display the current offset value.
Step 6 Press [▲] key or [▼] key to change the offset value.
NOTE: the offset can be adjusted from -1024 to 1024.
Step 7 Press and hold [◄] key for 1 second or more to return to the phase display.
Step 8 Press [◄] key to return to the display of the Fn006.
----End
Fn007 (Software version display)
The following are the steps to display the software versions.
Step 1 Press [M] key several times to select the Utility Function Mode.
Step 2 Press [▲] key or [▼] key to select the function number Fn007.
Step 3 Press [◄] key to display the software versions.
Step 4 Press [M] key serval time to display between DSP version, FPGA/CPLD version, Voltage class and Structure code.
Step 5 Press [◄] key to return to the display of the Fn007.
----End
Fn009 (Load inertia identification)
This utility function often used for tuning, refers to the section 1.
Fn010 (Absolute encoder multi-turn reset)
Step 1 Press [M] key several times to select the Utility Function Mode.
Step 2 Press [▲] key or [▼] key to select the function number Fn010.
Step 3 Press [◄] key, and Panel Operator displays as below.
Step 4 Press [M] key to reset the absolute encoder multi-turn data.
Step 5 Press [◄] key to return to the display of the Fn010.
----End
Fn011 (Absolute encoder alarm reset)
Step 1 Press [M] key several times to select the Utility Function Mode.
Step 2 Press [▲] key or [▼] key to select the function number Fn011.
Step 3 Press [◄] key, and Panel Operator displays as below.
Step 4 Press [M] key to reset the absolute encoder multi-turn data.
Step 5 Press [◄] key to return to the display of the Fn011.
----End
Fn017 (Auto-tuning tool)
This utility function often uses used for tuning, refers to the section 10.9.2 Auto-Tuning Tool.
Fn018 (PJOG operation)
This utility function often used for trial operation, refers to the section 9.5 Program Jogging.