Konwersja projektu z serii T na nowe modele

Streszczenie: Przeniesienie projektu z paneli serii T (obsługiwanych tylko przez EasyBuilder8000 do V4.43) na nowe modele: wgranie projektu z panelu, dekompilacja do .mtp, zmiana modelu w System Parameter Settings i pobranie do nowego HMI.
EN: How to convert a T series HMI project and download it to new models: upload, decompile to .mtp, change model, compile and download.

Dotyczy: panele HMI Weintek serii T; EasyBuilder8000 V4.43
Źródło: Weintek FAQ (materiały producenta), oryginalny tytuł: „How to convert T Series project and download it to new models?”

Since T Series HMI only support EasyBuilder8000 V4.43 and the previous versions, to convert the project and download it to new models, please upload the project using EasyBuilder8000 V4.43 or later versions first.

Please follow the steps below:
Step 1.
Open Project Manager > Upload, select the directory to store the uploaded project, and then click [Upload].

image.png

Step 2.
The uploaded xob file can be decompiled into mtp file, please open the mtp file after decompilation. 

image.png

Step 3.
Go to [System Parameter Settings > Model tab], select the new HMI model, and then compile and download the file to the new model

image.png