Skip to main content

9. FAQ (Frequently Asked Question)

9.1 Why there is no device listed after I run the client software?
Problem
Run the client software, there is no listed device.
Reason
● The device is powered off.
● Network exception.
Solution
● Check the device’s power connection (observe whether the indicator is unlit or not) to make sure the device is powered up normally.
● Check the network connection (the indicator is solid yellow if the network exception occurs) to make sure the device can be connected to the network normally, and make sure that the PC and the device are in the same network segment.

9.2 Why the image is very dark?
Problem
All black or too dark during live view.
Reason
● Insufficient brightness of light source.
● Too small value of exposure and gain.
Solution
● Increase the brightness of light source appropriately, or change to a brighter one.
● Increase exposure and gain appropriately.
Reason
Network circuitry speed is not 100 Mbps.
Solution
Check whether the network transit speed is 100 Mbps or not.

9.4 Why there is no image in the live view?
Problem
No image in the live view.
Reason
Enabled trigger mode, but there is no trigger signal.
Solution
Sent the trigger signal to the device, or disable the trigger mode.