9. FAQ (Frequently Asked Question)
9.1 Why the client software cannot list devices?
Reason
● The device is not powered on.
● Incorrect network cable connection.
Solution
● Check the device’s power supply by observing PWR indicator.
● Check the network connection by observing ETH indicator, and make sure that the device’s IP address is in the same network segment with the PC.
9.2 Why the live view is back?
Reason
● The brightness of the light source is not enough.
● Exposure time and gain value are too small.
Solution
● Increase Lighting Duration properly.
● Increase Exposure Time and Gain properly.
9.3 Why the image is not smooth in live view?
Reason
The network transmission speed is not up to 100 Mbps.
Solution
Check if the network transmission speed is up to 100 Mbps.
9.4 Why codes within the field of view cannot be recognized?
Reason
● Code types are not supported.
● Improper algorithm parameter settings.
Solution
● Check if code types are supported by the device or not.
● Adjust algorithm parameters properly.