Skip to main content

5. CHECK AND MAINTENANCE

Before performing any maintenance, be sure to read SAFETY PRECAUTIONS and understand the content.

image.png

 

5.1.DAILY CHECKS
Check the items below before daily operation as occasion demands

image.png

 

5.2.PERIODIC CHECKS AND MAINTENANCE
Check the items at the intervals recommended below based on the total time or the accumulated operating time, whichever comes first. Periodic checks keep the performance of the robot. The items below can be performed by yourself, or you can contact ESTUN for maintenance service.

image.png

image.png

image.png

image.png

 

5.2.1. Check the gas spring

image.png

Method 1: Check by gas-pressure meter
Check the gas spring with a gas-pressure meter. This robot needs a gas-pressure meter (model GA3500) to check the gas spring.

image.png

Procedures of checking the gas spring is shown below:
a) Adjust J2 joint to +20°, J3 joint to -20°, and then turn off the power supply.
b) Remove the cover plate and screw plug of the gas spring inlet.

image.png

Fig 5.2 check for gas spring (ER350-3300, ER500-2800, ER600-2800, ER700-2800-CE, UNO-700-2800 AC-CE)
c) A gas pressure detection device is mounted at the air inlet and the specified air pressure is given in the table below.
d) After confirming the air pressure, remove the detection device and reinstall the screw plug and cover plate.
Method 2: Through the software reminder function on the teach pendant

image.png

image.png

image.png

 

5.3.ADJUST THE BELT
J5 axis of ER500-2800 is drove by timing belt. The belt tense tends to reduce after a period of operation. This section describes how to strain the belt.

image.png

Procedures of straining J5-axis timing belt are shown below.
1.Disassemble the hexagon flat round head screw M6X12 under the cover on the right side of the small arm. Remove the cover and keep it in a proper place.
2.Unscrew the hexagon screw M8X30 on the mounting plate of J5-axis.
3.Adjust the device underneath the mounting plate (mainly adjust the M4 nut), make the screw firmly against to the mounting plate of J5-axis motor.
4.Test the tense on the side of the timing belt. Proper tense value is list in the table below.
5.Tighten the hexagon screw M8X30 on the mounting plate to remount the plate.
6.Use hexagon flat round head screw to fix the right side cover of the small arm. Tighten the screw.

image.png

image.png

image.png

Measure the belt tense according to frequency, as internal parameter set is not required.

5.4.REPLACING THE BATTERIES
The position data of each axis is preserved by the backup batteries. The batteries need to be replaced every 1 year. Also use the following steps to replace when the backup battery voltage drop alarm occurs.
Procedures of replacing the battery are shown below.
1.Press the emergency stop button before replacing the battery to prevent any accident.
2.Remove the cover of the battery case.
3.Take out the old batteries from the battery case.
4.Insert the new batteries into the battery case while observing the correct direction.
5.Re-mount the cover after replacing the batteries.

image.png

image.png

 

5.5.GREASING
Greasing is required to each part every 3 years, or for a cumulative operation time of 11520 hours, whichever occurs first, according to the following steps. Refer to the table below for the brand and quantities of the grease applied to each joint.

image.png

image.png

Recommend greasing gesture is list below.

image.png

 

Tab 5.9 Robot joint greasing angle (ER350-3300-CE, ER500-2800-CE, ER600-2800-CE, ER700-2800-CE, UNO-700-2800-AC-CE)

image.png

 

5.5.1. Position of oil inlet/outlet on each axis

image.png

image.png

image.png

image.png

image.png

image.png

image.png

 

image.png

image.png

image.png

image.png

image.png

image.png

image.png

 

5.5.2. Procedures of greasing
The following steps only applied to operation of reducers of J1, J2, J3, and J4 axes.
a) Teach each joint to run at a speed of 100% for 10-20min, to make the grease into oil with low viscosity.
b) Move the robot to the gesture of greasing, then turn off the power supply.
c) Put an oil recycle container beneath the grease outlet.
d) Remove the screw on the inlet and outlet of each joint.
e) Inject new grease via the oil inlet until new grease goes out of the outlet. The amount of oil injected should be equal to the amount that is discharged (including those discharged after warming up the machine).
f) Release the residual pressure in the grease groove according to section 5.5.3.
g) Install the screw to oil inlet and outlet with a torque of 13.7N·m.
If greasing is not performed properly, the internal pressure inside the grease bath may increase suddenly, which will damage the seal part, resulting in oil leakage and abnormal operation. Therefore, when performing greasing, observe the following precautions.
 Open the grease bath vent (remove the screw on the oil outlet) before greasing.
 Inject the grease/oil slowly without excessive force.
 Avoid compressed gas pump (powered by factory gas source) whenever possible.
 Use specified model of grease/oil. Unauthorized model of grease may cause damage to the reducer or other problems.
 When greasing is completed, make sure that there is no oil/grease leakage outside the outlet. and the grease bath is not pressurized. Then close the outlet.
 Clean the excess oil/grease on the floor to avoid accidents such as slipping or fire.

5.5.3. Procedure for releasing remaining pressure within the grease bath

Release remaining pressure with the following procedures. Attach bags under the oil outlet to prevent spilled oil/grease from splattering.
a) Power the robot, and operate at a 100% speed with full load for 4 hours continuously
b) Stop the running program of the robot at zero position, turn off the servo power with the teach pendant.
c) Disassemble the screw at oil inlet of each axis after safety confirmation. Do not face the screw when removing it, in case that oil with high pressure and high temperature ejects, resulting personnel injury.
d) Retighten the screw 3% seconds later after removing it, and clean up the oil around the screw with a clean cloth.
e) Be sure to complete pressure releasing of a robot (step c and step d) in 15 minutes. Otherwise, it should be repeated from step 1.

5.6.Oil leakage inspection

Maintenance Area
Insert a cloth or similar material into the gaps of each joint to check for any oil leakage from the oil seals. If oil leakage is observed, please wipe it clean.
⚫ Depending on the operating conditions and surrounding environment, oil may leak from the outer lip of the oil seals. When accumulated oil forms droplets, it may drip during certain movements. Prior to operating the robot, please wipe off any oil accumulation on the underside of the oil seals.
⚫ Additionally, if the temperature during operation is excessively high, the internal pressure in the joint chambers may increase. In such cases, after the operation, please open the oil filling port once to restore the internal pressure. (Do not open or close the oil filling port while the machine is in a cooled state)
⚫ If oil leakage persists even after frequent wiping, please refer to 7.2 Troubleshooting.

image.png