7. Tuning
Tuning is the process of satisfying the servo performance by adjusting the parameters involved in the control law.The process of tuning is usually an iterative process; the figure below shows the general flow There are various indicators used to evaluate ser...
8. Fully Closed Loop Operation
With a fully-closed system, the encoder on the motor is used in conjunction with an external encoder (external to the motor) is used to detect the position of the load. This is also known as dual encoder feedback. Below is a block diagram of Fully-Closed Loop ...
9. Appendix
9.1 EtherCAT Communications9.1.1 IntroductionEtherCAT is a real-time Industrial Ethernet technology originally developed by Beckhoff Automation. The EtherCAT protocol which is disclosed in the IEC standard IEC61158 is suitable for hard and soft real-time requi...
10. Revision History
Hikrobot- ID5000 Series Industrial Code Reader User Manual
1. Appearance
2. Interface and Indicator
2.1 12-Pin InterfaceRead the following section to get definitions of 12-pin interface. 2.2 Indicator StatusRead the following section to get the indicator status of the device.
3. I/O Wiring
3.1 Input SignalThe device's LineIn 0/1/2 is opto-isolated input, and their internal circuit is as follows 3.2 Output SignalThe device's LineOut 0/1/2 is opto-isolated output, and their internal circuit is as follows. 3.3 Input Signal WiringThe de...
4. Installation
4.1 Installation PreparationYou need to prepare following accessories before installation. 4.2 Install DeviceBefore You Start● Make sure the device in the package is in good condition and all the assembly parts are included.● Make sure that all the related ...
5. Device Connection
Device connection to the client software is required for device’s configuration and remote operations. This section introduces how to install the client software, set PC network, connect the device to the client software, etc. 5.1 Install Client SoftwareIDMVS ...
6. Client Software Layout
After connecting to the device, the client software can read the device information and display it. You can set device parameters in device configuration area.
7. Device Mode Settings
The device supports 3 types of operating modes, including Test, Normal, and Raw. You can select different modes in live view window according to actual demands. You can click in the live view window to view images and the code reading effect. If the effect ...
8. Device Settings
You are recommended to complete device settings in following order: Device Connection → Image Settings → Algorithm Settings → I/O Control Settings → Data Processing → Communication Settings → Configuration Management. ● Device Connection: It tells you how to ...
9. Device Operation
The device operation section introduces some basic device operations about how to start live view, acquisition and recording, add cross line in the image, split window, view reports, etc. 9.1 Live ViewYou can view the real-time image in the live view window.C...
10. Device Maintenance
10.1 Update FirmwareThe device supports updating firmware via the client software. Select the device to be updated in the device list, right click the device, and click FirmwareUpdate. Click to select update file from local PC, and click Update to update firm...
11. FAQ (Frequently Asked Question)