Recently Updated Pages
40. Battery Replacement for eMT / i series
The eMT-3000 / i Series takes one coin type of CR2032 lithium battery to keep the RTC running. Ba...
39. How to clear history event log files?
The HMI memory of MT8000/6000 series is able to store event log data. There are three ways to cle...
38. How to use SPRT printer
MT8000/6000 series support SP-M, D, E, F and SPRT series printer. Please refer to instructions be...
37. How to backup a project?
An EasyBuilder Pro project contains the source project file (*.mtp), and a number of library file...
36. Auto. Replace PLC Address by Tag Name after Convert EB500 Project to EasyBuilder Pro
After using convert function to convert EB500 project to EasyBuilder Pro, the tag will lose. The ...
35. Remote control HMI with smartphones
For setting HMI VNC function, please refer to the here.ftp://ftp.weintek.com/MT8000/eng/FAQ/FAQ_2...
34. HMI TCP Port List
This FAQ introduces the TCP ports used for certain HMI features. Feature Default Port Note ...
33. How to calibrate for MT8000 / MT6000?
For MT8000/MT6000 T and i series, users can set DIP Switch 1 to “ON” and the rest remain “OFF”, t...
32. HMI Operating Temperature
MT6000/8000 HMI operating temperature ranges from 0° to 45°C (32°~113°F). If the unit is under 0°...
31. How to download project through HMI name?
If users would like to download project through Ethernet, there are two ways for selection. One i...
30. How to Enable/Disable System Setting Bar?
EasyBuilder Pro supports the function of using system tag [LB9020] to enable/disable system setti...
29. How to install USB driver of HMI i Series
HMI i Series support the function of using a USB to mini USB cable to download/upload projects fr...
28. How to use VNC server?
Enable VNC server and set login password on HMI System Settings / VNC server tab. 2. Install J...
27. Criterion of saving the data to HMI memory and external device
● Data under Real time mode will be lost if HMI shut down. (Real time means no settings in histor...
26. Build font files failed
How to prevent “Build font files failed” in Windows XP? If user is not login Windows XP as admini...
25. How to display square/circle on MT8070T
For MT6070T and MT8070T have particular aspect ratio (resolution: 480*234), before to display squ...
24. How to use security function?
The following is an example to illustrate the steps of security feature: Step 1First of all, crea...
23. How to translate excel file to *.emi format
1. Open “Recipe/Extended Memory Editor” 2. Open *.emi file and input the data, then press OK. ...
22. How to uncompress file?
This FAQ introduces how to uncompress .ecmp / .cmp file to .emtp / .mtp file, and then edit the f...
21. How to Download Project to HMI via Ethernet?
This FAQ explains how to download project file to HMI via Ethernet, and it can be applied to eMT,...