Advanced Search
Search Results
755 total results found
1. Safety
Robots generally have requirements which are different from other manufacturing equipment, such as larger working areas, high-speed operation, rapid arm movements, etc., which can pose safety hazards. Read and understand the instruction manuals and related doc...
2. Product Confirmation
2.1 Product confirmation2.1.1 Contents confirmationConfirm the contents of the delivery when the product arrives. Standard delivery includes the following four items: (information for the content of optional goods is given separately). Robot Control cabinet...
3. Product Use
It is necessary to install and connect the product before use.3.1 Connection methodsPrior to use, please ensure that the robot, control cabinet and teach pendant are properly connected and that the equipment is available. For connection methods, please refer t...
4. Introduction to System Functions
The interaction between the robot controller and the user is performed through the programming pendant.Programming pendant is an important part of the robot control system. The operator manually teaches using the programming pendant, controls the robot to prod...
5. Introduction to Variables
Different types of variables are supported by different domains, which are detailed as follows: System Domain: The system predefined variables, which cannot be edited. Global Domain: IO data type, PLC data type, socket data type, position data types, area da...
6. Introduction to Commands
6.1 Motion commandsThe list of motion commands is shown in Figure 6-1.Figure 6-1 List of motion commands MovJ - Point-to-point motion commandIt indicates that each joint of the robot performs point-to-point motion. The end trajectory of the robot is an irregu...
7. Advanced Functions
7.1 Multi-type Area MonitoringFunction OverviewBy setting up safety zones, the position of the robot can be monitored in real time under a variety of working conditions, minimizing the likelihood of collisions. WorkArea:All CheckPoints (TCPs) of the robot ar...
8. FAQs
8.1 The way to find the corresponding control cabinet manual based on nameplateThe control cabinet model is shown in the figure below: SolutionsStep 1: Find the nameplate of the control cabinet. Take the C2E control cabinet manual as an example. Step 2: Ba...
9. Annexes
9.1 Privilege assignment of programming pendant 9.2 ModbusTCP control interface data sheet 9.3 List of Alarm Information
Revision History
Preface
OverviewThis document is applicable to the control system RCS2 V1.30 and above versions. It describes the structure definitions, variable types, and parameter meanings in the RCS2 command system of ER series robots, aiding users in gaining a profound understan...
1. System Introduction
1.1 System overviewThe command system file structure is divided into three parts: Project, Program, and Data. Among them, the data is further divided into four domins: System, Global, Project and Program. Program code is saved in files with the following exten...
2. Variable Data Types
Different types of variables are supported by different domains, which are detailed as follows: System Domain: The system predefined variables, which cannot be edited. Global Domain: IO data type, PLC data type, socket data type, position data types, area da...
3. Commands
3.1 Motion commandsThe list of motion commands: MovJIt indicates that each joint of the robot performs point-to-point motion. The end trajectory of the robot is an irregular curve, and the IO command can be operated when the command operates to an end. Descri...
1. Software Installation and Configuration
1.1.Software Installation StepsOpen the software installation package and install SetupEstunEditor-EN-2.4.1.exe offline programming software. Double-click to display the EstunEditor-EN-2.4.1 installation wizard. Click 'Next' directly, choose the components t...
2. User Management System
2.1.Login InterfaceUpon system startup, there is a login window where users can enter their username/password to log in or choose to cancel the login. Canceling the login will result in logging in with limited guest privileges by default.⚫ Username/Password: T...
3. Controller Module
3.1.Controller ConnectionClick the button located in the blue-boxed area in the image to establish a connection with the controller. Click to open the connection dialog as shown below. Based on your requirements, select the physical controller and the virtua...
4. Functions of Project Management
When opening the Editor software, all locally existing programs will be listed.The function pages are shown in the following image: After connecting to the controller, the programs on the controller will also be listed, as shown in the image below: (1) Works...